HVAC Clamp Meter
CL440
This product is no longer in production
- CL440 HVAC Clamp Meter is an automatically ranging true root mean square (TRMS) digital clamp meter
- Digital clamp measures 600.0 A AC current and inrush current
- Test leads measure 750V AC/600V DC voltage, DC micro amp, resistance, continuity, frequency, duty-cycle, capacitance, and diode tests
- K-Type thermocouple port for measuring temperature from -328 to 2462 Degrees Fahrenheit (-200 to 1400 Degrees Celsius)
- Detect AC current with non-contact voltage tester integrated into the clamp jaw
- Backlit LCD with dual V + A function allows simultaneous viewing of voltage and current measurements
- Dedicated mode for capturing DC micro amp and inrush current
- CAT IV 600V, CAT III 750V, Class 2, Double insulation safety rating
- Includes right-angle input test leads, push-on alligator clips, K-type thermocouple, storage pouch, instruction manual, and 3 x AAA batteries
- Can be used with Magnetic Hanger Cat. No. 69417 (sold separately) for hands free operation
ÌÒ×ÓÊÓƵ CL440 Clamp Meter is an advanced HVAC clamp meter with automatically ranging true root mean square (TRMS) for maximum accuracy. The meter measures AC current, inrush current, AC/DC voltage, DC microamps, resistance, continuity, frequency, capacitance, temperature, diodes, and more. This Digital Clamp Meter comes with right-angle input test leads, push-on alligator clips, K-Type thermocouple, storage pouch, instructional manual, and 3 x AAA batteries.
Specifications
Type:
HVAC TRMS Clamp Meter
Application:
Measures AC Current, Inrush Current, AC/DC Voltage, DC Microamps, Resistance, Continuity, Frequency, Capacitance, Temperature, Diodes, and More
Special Features:
Automatically Ranging True Root Mean Squared (TRMS) Measurement Technology for Accuracy; NCVT; Added Temperature
Material:
ABS and Electrical Components
Batteries:
3 x AAA
Auto-Power Off:
Yes
Jaw Size:
2'' (5.1 cm)
Drop Protection:
3.3' (1 m)
Display:
6000 Count LCD
Functions:
TRMS, AC Current, Inrush Current, AC/DC Voltage, DC Microamps, Resistance, Audible Continuity, Frequency, Capacitance, Temperature, Non-Contact Voltage Testing, Diodes, Min/Max, Data Hold Capability
Voltage:
750V AC; 600V DC
Frequency:
60 kHz
Current:
600A
Capacitance:
6.000mF
Ohms (Resistance):
60²ÑΩ
AC Voltage:
750V
DC Voltage:
600V
DC Polarity Indicator:
Yes
DC Micro-Amp:
600µ´¡
Temperature Range:
-328° to 2462°F (-200° to 1350°C)
Standard:
CAT IV 600V, CAT III 750V, Class 2, Double Insulation Safety Rating
Included:
Right-angle Input Test Leads, Push-on Alligator Clips, K-Type Thermocouple, Storage Pouch, Instruction Manual, and 3 x AAA Batteries
Overall Length:
10.04'' (25.5 cm)
Overall Height:
1.57'' (4 cm)
Overall Width:
3.77'' (9.6 cm)
Weight:
14.2 oz (402 g)
UPC:
092644693359
Warnings
- Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
- Read, understand and follow all instructions, cautions and warnings attached to and /or packed with all test and measurement devices before each use.
- Do not use the meter during electrical storms or in wet weather, and do not use the meter or test leads if they appear to be damaged.
- Before each use verify meter operation by measuring a known voltage or current.
- Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.