Infrared Thermometer with GFCI Receptacle Tester
IR1KIT
- Infrared Thermometer (Cat. No. IR1) has an optical resolution (distance-to-spot) of 10:1
- GFCI Outlet Tester (Cat. No. RT210) detects common wiring problems in standard and GFCI receptacles
- Both products have a drop protection to 6.6-Foot (2 m)
- Infrared Thermometer has a wide measurement range from -4 to 752-Degree Fahrenheit (-20 to 400-Degree Celsius)
- Not a medical device; thermometer is NOT intended for use on people or animals
- Fixed emissivity of 0.95 for the Infrared Thermometer
- Infrared Thermometer includes custom pouch and a 9V battery
- Auto Power-Off feature of the Infrared Thermometer conserves and extends battery life
- Infrared Thermometer is Certified to IEC EN 61326-1.2006, EN608251.1994+A2.2001+A1.2002
The ÌÒ×ÓÊÓƵ IR1KIT includes the Infrared Thermometer (Cat. No. IR1) and GFCI Receptacle Tester (Cat. No. RT210). The IR1 infrared thermometer with a targeting laser has a wide measurement range from -4 to 752-Degree Fahrenheit (-20 to 400-Degree Celsius) and a 10:1 distance-to-spot ratio. The RT210 GFCI Receptacle Tester detects common wiring problems.
Specifications
Type:
Infrared Thermometer with Targeting Laser
Application:
Temperature Measurement and Electrical Testing
Special Features:
Target Laser on IR1
Material:
Plastic Housing, Electronic Components
Batteries:
1 x 9V
Distance to Spot:
10:1
Accuracy:
±4° F or ±2%; Accuracy Below Freezing is ±4° F Plus 0.2 Degrees Per Degree Below 32° F
Display:
Digital Backlit
Display Resolution:
0.1F (0.1 C)
Response Time:
<0.25s
Degree Format:
F or C
Range:
-4° to 752° F (-20° to 400° C)
Standard:
IR1: EN 61326-1:2013, EN 608251:2014, 21 CFR 1040.10 and 1040.11, Class II Laser, CE
Drop Protection:
6.6' (2 m)
Included:
RT210 GFCI Receptacle Tester; Custom Pouch; 1 x 9V Battery
Overall Length:
6.01'' (15.3 cm)
Overall Width:
1.24'' (3.1 cm)
Overall Height:
4.14'' (10.5 cm)
Weight:
7.1 oz (201 g)
UPC:
092644693199
Warnings
- Read, understand and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.
- LASER RADIATION, Class II laser. Do NOT stare into beam. Exposing eyes to laser radiation can result in severe and permanent eye injuries.
- NEVER look directly into the laser beam emitted by this instrument.
- Usage of this tester in any way other than that specified by the manufacturer can impair safe operation, resulting in severe injury or death.
- Thermometer is NOT intended for use on people or animals.